<p>Vetotop UC363 is a two-component, solvent-free aromatic polyurethane intermediate coat and waterproofing membrane. The product needs to be overcoated with Vetotop UC370 or Vetotop UC371 or Vetotop UC372 or Vetotop UC373 for optimum performance and scratch resistance. The product’s flexibility enables it to perform in a wide range of flooring applications.</p>
The surface should be sound, clean, free from loose material, grease, laitance, dirt curing compound, etc. Laitance and weak surface layer shall be removed using mechanical methods such as grinding or blasting to provide a sound, well-profiled surface. Repair all necessary surfaces before application by using epoxy mortar from the Vetorep ER range. New concrete floors shall be at least 28 days old with a moisture content of less than 5% (shall earlier application be required testing of substrate for moisture conditions shall be made).
Prime concrete substrates with Vetoprime EP691, Vetoprime EP490, Vetoprime EP491.
In a separate mixing vessel, use a slow speed mixer to mix the base, hardener for 3 minutes. Mix these components in the quantities supplied, ensuring that all containers are scraped clean. Do not add solvent thinners at any time.
Apply Vetotop UC363 by a pin leveler or airless spray to the dry surface. The application should be at a rate of 1.25 m2/liter per coat.
The application should not be carried out when relative humidity exceeds 75% or when the surface temperature to be coated less than 3°C above the dew point.
Vetotop UC363 can be applied as a single coat or dressed with Vetograin products to give a slip-resistant finish.
For more information, please refer to Vetograin Technical Data Sheet.
Expansion joints in the existing substrate must be retained and continued through the Vetotop UC363 topping. Saveto has a range of joint sealants specifically designed for flooring (see Vetoflex PS782 product data sheet).
Clean tools and equipment with Vetonit Solvent XX300 immediately after use.